You save $1,144.93
Free shipping on 95% of products Australiawide
Next Day Shipping
Free & Fast Shipping

GUARANTEED SAFE CHECKOUT

safe-checkout

Socomec : Netys RT 1100 rack 2U/tower UPS

The NETYS RT 1100 rack 2U/ tower UPS is the complete solution for IT infrastructures. It is the solution for switching, storage, servers and networking devices, VoIP communication systems, structured cabling systems, control systems and Video surveillance systems

ÂA Features

Simple to install

âA‚¬A¢ IEC input and output connections (1100âA‚¬A˜3000 VA) or terminal input and output connections with built-in magnetothermal input switch (5000-11000 VA).
A¢A‚¬A¢ Compact footprint for installation in rack cabinets.
A¢A‚¬A¢ Attractive design.

Easy to use

âA‚¬A¢ No configuration necessary on first startup.
A¢A‚¬A¢ Wide range of communication protocols for integration into LAN networks or Building Management Systems (BMS).
A¢A‚¬A¢ Clear LED interface with buzzers that immediately indicate the operating status of the UPS, even for less specialist users (1100âA‚¬A˜3000 VA).
A¢A‚¬A¢ LCD display with menu available in 6 languages (5000-11000 VA).

Meets practical needs

âA‚¬A¢ Online double conversion technology with sinusoidal waveform, completely filters out all disturbances from / to the mains power
supply and ensures maximum protection of the utility.
A¢A‚¬A¢ Modular battery extension (EBM) to meet all back-up time requirements, even after installation.
A¢A‚¬A¢ Possibility of 1+1 parallel redundant configuration to maximise the availability of critical utilities, even in the event of a module breakdown (5000âA‚¬A˜11000 VA).

ÂA 

ÂA 

Specifications

  • Online Double Conversion

  • 1100VA

  • ÂA  Universal tower + 2U rack inc rail kit,

  • USB & RS232 comm's port & cable

  • Optional SNMP card available

  • 6 x 10A IEC outlets, includes 3 pin Aust input cord + 1 x Aust output conversion cord & 1 x IEC cord

ÂA 

ÂA 

Standard and Option Features

Standard electrical features

âA‚¬A¢ Built-in backfeed protection.
A¢A‚¬A¢ Protection against atmospheric phenomena (NTP) for telephone / ADSL modems.
A¢A‚¬A¢ RJ11 connection for Emergency Power Off (EPO).
A¢A‚¬A¢ Connection for battery extension modules.
A¢A‚¬A¢ Port for parallel operation (5000-11000 VA).

ÂA 

Electrical options

âA‚¬A¢ 1+1 parallel module (5000-11000 VA).
A¢A‚¬A¢ Manual bypass without interruption (5000-11000 VA).
A¢A‚¬A¢ Battery extension modules.

Standard communication features

âA‚¬A¢ LOCAL VIEW: ideal UPS monitoring and shutdown point-to-point solution for WindowsÂA® operating system.
A¢A‚¬A¢ UNI VISION: software for the control and automatic shutdown of applications connected to Linux.
A¢A‚¬A¢ UNI VISION PRO: advanced user interface via serial link and multiple shutdown management for several operating systems.
A¢A‚¬A¢ HID: UPS management based on WindowsÂA® embedded service - USB interface (1100-3000 VA).
A¢A‚¬A¢ MODBUS/JBUS RTU.
A¢A‚¬A¢ RT-VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems (5000-11000 VA).

Communication options

âA‚¬A¢ RT-VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems (1100-3000 VA).
A¢A‚¬A¢ Dry-contact interface.

Technical Data

Connections

ÂA 

Connections

ÂA 

1. Mains input socket (IEC 320)
2. Fan
3. Output socket (full power)
4. Telephone / modem line protection
5. EPO (Emergency Power Off) input
6. RS232 interface (JBUS protocol)
7. USB port
8. Input protection
9. Output sockets (IEC 320 - 10 A)
10. Battery extension connector
11. Slot for optional communication boards
12. Battery extension connector
13. Output terminals
14. Input terminals
15. Input switch
16. RJ45 LAN ethernet connector
17. Parallel port connector

ÂA 

ÂA 

Battery extension

ÂA 

Netys RT 1100-3000 VA - Battery extension

ÂA 

ÂA Netys RT 5000-11000 VA - Battery extension

ÂA 

Control panel

ÂA 

Control Panel


1. Yellow LED lit. Operation in bypass mode
2. Green LED lit. Mains healthy
3. OFF button
4. Green LED lit. Normal operation (inverter in-line)
5. ON / TEST and buzzer override button
6. LED bar. Depending on the situation, this indicates either the charge level or the capacity of the battery
7. Navigator buttons
8. Alphanumeric LCD display
9 Green LED lit. Status of the load.
A‚A 

ÂA 

ÂA 

Technical data

ÂA 

Power 1100 VA / 800 W 1700 VA / 1200 W 2200 VA / 1600 W 3000 VA / 2100 W 5000 VA / 4500 W 7000 VA / 5400 W 9000 VA / 7200 W 11000 VA / 9000 W
Architecture PFC and automatic bypassonline double conversion VFI with input
Parallel redundant function - - - - 1+1 1+1 1+1 1+1
Input
Voltage 230 V (1ph) 160~275 Vac; up to 130 Vac @70% load 230 V (1ph) 181~280 Vac up to 100 Vac @50% load
Frequency 50/60 Hz +/-10% (Auto-Selectable)
Power factor / THDi >0.98 / <6% >0.99 / <5%
Output
Voltage 230 V (1ph) selectable 200 / 208 / 220 / 240V - 50 or 60 Hz + /- 2 % (+/- 0.05 Hz in battery mode)
Rendement up to 91% online mode up to 92% online mode
Overload capability up to 105% continuously; 125% x 3 min; 150% x 30 sec up to 105% continuously; 125% x 5 min; 150% x 30 sec
Output connections 6 x IEC 320-C13 (10 A) 6 x IEC 320-C13 (10 A) + 1 x IEC 320-C20 (16 A) terminals
Battery
Standard autonomy* 8 12 8 10 8 6 8 6
Voltage 24 Vdc 48 Vdc 48 Vdc 72 Vdc 192 Vdc 192 Vdc 240 Vdc 240 Vdc
Recharge time < 6h to recover 90% capacity < 6h to recover 90% capacity
Communication
Mimic panel LED LCD 6 languages
RS232 (DB9 port) Jbus protocol âA‚¬A¢ ÂA âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢
USB HID protocol âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ - - - -
WEB/SNMP (Ethernet RJ45 port) option option option option âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢
COMM slot âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢
Dry contacts card option option option option option option option option
EPO input (RJ11 port) âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢
Modem/ADSL surge protection âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ - - - -
Parallel port - - - - âA‚¬A¢ âA‚¬A¢ âA‚¬A¢ âA‚¬A¢
Standards
Performance & topology EN 62040-3 (VFI-SS-111)
Safety / EMC EN 62040-1 (TÃœV-GS certified) EN 62040-2
Product certifications CE, TÃœV-GS, C-Tick
IP rating IP20
Environment
Operating ambient temperature from 0A‚A°C to +40A‚A°C (from 15A‚A°C to 25A‚A°C for best battery life)
Storage temperature range from -15A‚A°C to +50A‚A°C (from 15A‚A°C to 25A‚A°C for best battery life)
Relative Humidity 0-90% non-condensing
Noise level (ISO 3746) < 45 dB < 55 dB
Dimensions & weight
UPS size std (W x D x H) 88.7 x332 x440 mm 88.7 x430 x440 mm 88.7x 430x 440ÂA  mm 88.7 x608 x440 mm 177.4 x670 x440 mm 177.4 x670 x440 mm 261.2 x623 x440 mm 261.2 x623 x440 mm
UPS size RACK 2U 2U 2U 2U 2U+2U 2U+2U 3U+3U 3U+3U
UPS weight std 13 kg 21 kg 22 kg 31 kg 15.5+40 kg 16+40 kg 19.5+66 kg 20+66 kg
EBM module size (W x D x H) 88.7 x332 x440 mm 88.7 x430 x440 mm 88. 7 x430 x440 mm 88.7 x608 x440 mm 88.7 x608 x440 mm 88.7 x608 x440 mm 130.6 x623 x440 mm 130.6 x623 x440 mm
EBM module RACK 2U 2U 2U 2U 2U 2U 3U 3U
EBM module weight 16 kg 29 kg 29 kg 43 kg 40 kg 40 kg 66 kg 66 kg

* @ 75% of nominal load.ÂA 

ÂA 

ÂA 

Parallel redundant operation for business continuity

ÂA 

To achieve the highest level of availability and to power critical utilities, NETYS RT UPS modules above 3 kVA can be configured for 1:1 redundancy.
Redundant operation (1+1) means: the system incorporates one more UPS module than is needed to protect the load ; in the event of a breakdown, it guarantees sufficient power supply capacity to the load by maintaining online protection.
Parallel technology is based on the principle of load sharing, whereby both units are always kept active.
In a redundant configuration, overall system availability is much higher than a conventional UPS system using similar technology. 1+1 redundant configuration does not require additional circuits and can therefore be set up at a later date, simply by using two UPS modules and a collector / manual bypass module which simplifies cabling and maintenance of the UPS installation.
To further streamline the solution, it is also possible to select between operation with separate battery or shared battery, which is extremely useful in the case of applications requiring high levels of autonomy.

ÂA 

Warranty

2-year limited warranty.

Why 4Cabling?

  • AustraliaâA‚¬A„¢s leading importer & wholesaler of 19âA‚¬A� server racks, copper, ethernet cable, fibre optic leads & structured networking products
  • ISO 9001, NSW Govt. & GITC (QLD Govt.) approved supplier
  • Secure online shopping 24/7
  • A loyal customer base of 100k+ who trust us for their data & electrical needs
  • Over 3000 quality products in stock ready to go
  • All products are approved as per local Australian standards
  • Warranty & peace of mind return policy
  • Lightning-fast delivery nationwide
  • Expert advice
  • Proudly 100% Australian owned & operated

Please take care when placing orders. Customer service is our highest priority however we process large volumes of orders every day and due to the nature of our automation in most cases we are unable to stop an order shipping once the order is placed. We don't place many restrictions on returns (see full returns and cancellations policy Below  however if you decide you wish to cancel or return an order the return shipping costs must be paid by you. (Excluding warranty items or any cases we make an error). For the most cost effective returns on items up to 25kg and up to 1.2M at the longest point we recommend www.sendle.com.au

Cancellations of "pay over time" orders may incur a cancellation fee as some providers do not refund merchant fees. We only charge the amount we are charged.

For your protection we offer free transit insurance on all orders. Should your item arrive damaged please let us know so we can provide you with the claims procedure. 

Returns of larger items can be very expensive so please choose carefully. We are here to help with any questions you may have prior to ordering. 

Due to some carrier restrictions there are certain postcodes that we are unable to deliver to. Please do not place an order if you are located in one of the postcodes below for all items. Please scroll down to bottom of page to check bulky item over 22kg (in dead weight or cubic weight) postcode exclusions. We try to ship all orders within 1 business day however it can take up to 3 business days. (This is more common in peak periods) Once you receive your tracking information most courier tracking sites will provide an ETA for delivery. We are unable to offer express or air shipping currently.

We partner with the following carriers:

shipping-courier

RETURN POLICY

You're entitled to a refund, replacement or repair if:

  •  The item is faulty or damaged
  • You were sent the wrong item
  • You were sent the wrong size
  • The item is significantly different from the product images and description

You are NOT entitled to a refund because:

  • You just changed your mind
  • You found the product cheaper at another store
  • You don't like it
  • You bought the wrong size


The product has a fault that you knew about before you bought it.This includes instances where the fault was listed in the description.


For Electronics , We don't take returns on electronics product. If product is faulty we will send replacement. There will be no refund on electronics product.

we are not accepting any return on any items because of restricition of lockdowns.
please before you place an order make it sure you placed the correct item.

Recently Viewed Products

Just added to your wishlist:
My Wishlist
You've just added this product to the cart:
Go to cart page

#title#

#price#
×